Medical Online Low Frequency UPS , Double Conversion 100KVA To 400KVA
Product Details:
Place of Origin: | Shenzhen China |
Brand Name: | HRD/ OEM /ODM |
Certification: | ISO9001:2008,CE |
Model Number: | PE33160II,PE33200II,,,PE33400II |
Payment & Shipping Terms:
Minimum Order Quantity: | 2pcs |
---|---|
Price: | 18000usd/pcs |
Packaging Details: | wooden case with pallet |
Delivery Time: | 3 weeks after down payment |
Payment Terms: | TT or LC |
Supply Ability: | 200PCS/ MONTH |
Warranty: | 3 years after shipment |
Detail Information |
|||
Product Name: | Online Uninterruptible Power Supply | Computer Monitors Port: | Standard S232,optional ODBUS |
---|---|---|---|
Mean Time Before Failure(MTBF): | Above 200,000 Hours | Noise DB: | 54 ~ 62db |
Protection Class (EN 60529): | IP20 | Inlet And Outlet Of The Wire Way: | Bottom /rear |
High Light: | online ups power,low frequency online ups,medical online low frequency ups |
Product Description
Medical Online Low Frequency UPS , Double Conversion 100KVA To 400KVA
Introduction: POWER EXCELLET (Ⅱ) is upgraded DSP controlled Online LF UPS with output isolation transformer. It can be your perfect large capacity power shield for your critical and industrial load.
QUALITY POWER SUPPLY
HRD PE(II)series is an On-Line double conversion (VFI) UPS with isolation output transformer, unit capacity from 10KVA to 400KVA. It is immune to the interferences on the electric power supply line as it has special input and output filters. World leading DSP technology, with high speed DSP processor are adopted to guarantee system’s high stability and giving stable output power supply for all kinds of harsh load.
PERFECT APPLICAITON: Middle and large data center, Telecom, Finance, Traffic, Defense, Medical, Education, Energy, Manufacture, Industry, etc.
MAXIMUM RELIABILITY
MTBF >200,000h.
The advanced DSP technology appliance considerably improves reliability, since a reduction in electronic components lowers the likelihood of breakdowns. Digital control is provided by the microprocessor that, in the PV(II) series controls all the internal parameters, thus increasing reliability and performance. In parallel connections, digital control ensures balance of the currents, which generally change over time due to phenomena such as vibrations and temperature, between the UPS units and the exchange of information with no need for manual tuning. PV(II) has been designed so that it can be connected in parallel even after the installation of the first unit. The power availability can be increased thanks to various configurations available such as the parallel configuration, the Dual Bus function and the Dynamic Dual Bus system.
HIGH SPEED DSP PROCESSOR: Ensuring the operation more faster and more stable
OUTPUT 100% UNBALANCE LOAD
The UPS can accept 3phase 100% unbalance load to satisfy kinds of load configuration.
ECO function: under good power condition, UPS can work in ECO mode, efficiency reach 98%, green and energy saving;
UPS FOR INDUSTRIAL LOADS
PV(II) series with its strong overload capability, output galvanic isolation and low harmonic current distortion, is the ideal solution for industrial applications.
Thanks to the high battery current, PV(II) Series is suitable to work with large battery banks as it can guarantee recharging in 10 hours as recommended by the battery manufacturer.
OPERATING FLEXIBILITY:All power ratings of the PV(II) series can also be used as Frequency Converters 50 to 60 Hz and vice versa.
COLORFUL MULTIFUCTIONAL PANEL
The 7 inch colorful multifunctional panel allows easy and humanized operation of the UPS. It gives access to the most important parameters: status and alarms, control commands, input, output, battery measurements (power, current, voltage, frequency and temperature) and settings. The PE(II) series’ diagnostics system includes up to 128 alarms or messages allowing precise and detailed identification of any event.
Advanced Battery Management (ABM)
Optimal battery management includes:
- Periodic battery test, and automatically transfer between boost charging and float charging to extend battery lifespan
- Automatically adjusting the battery charging current according to battery capacity
- Recharge temperature compensation (optional)
- Remaining back up time display
MAXIMUM SAFETY FOR PERSONNEL
The back feed protection device prevents any voltage back feed in the upstream distribution board, thus ensuring the safety of the maintenance personnel.
FULL FRONT ACCESS AND CONVENIENT CABLE CONNECTION
Full frontal access is for all power and electronic components, which reduces the floor space required and consequently reduces the installation costs.
Configured with top and bottom cable connection
PERFECT HUMAN-MACHINE COMMUNICATION
UPS Monitor software displays the most important information such as the input and output voltage, the load applied, the remaining back-up time, etc., in the form of bar graphs. The software is able to provide information even in the event of a failure, in support of the fault diagnostics. The UPS Monitor software can be used to program the automatic shutdown of all open systems in the event of a prolonged black out. PV(II) can also operate with a network agent for applications on LAN or WAN networks.
The UPS contains the following hardware interfaces:
- RS232 /RS485 interface,
- Dry contacts: battery low,battery discharge,bypass/breakdown
- EPO (Emergency Power Off) contact for UPS shutdown using the remote emergency button.
- SNMP card(optional)
ADVANCED PARALLEL
Maximum parallel up to 8 units and share the common battery pack.10-100kva parallel can be with parallel card only ; 120kva-400kva, parallel card with weaver reactance and different capacity UPS can be also be parallel;
DYNAMIC DUAL BUS SYSTEM
Two independent systems set in Dual Bus Configuration can be merged together at any time for system expansion or maintenance. This provides a lot of flexibility in your installation in case of maintenance or when it is necessary to change the redundancy level of both systems.
EVENT LOG: 10000 historical events can be saved, which is easy for tracing UPS operation status and useful for maintenance
PE II series is a fully DSP controlled high-level industry UPS with capacity up to 800kVA.
Based on nowadays the most advanced DSP(TI 2833X CPU), MCU, CPLD ect ,and more than 20nos leading innovative technology ,this UPS has become a perfect robust and cost-effective power solution, optimizing the minimal operating cost for end users.
Its extremely high reliability can solidly ensure the continuous availability of power and safe operations for all types of critical load.
Fully DSP technology with extremely low cycle current,it can be parallel up to 8 units for redundancy or capacity expanding purpose.
Super reliability and excellent performance based on innovative solution,it definitely ensures your business away from any power problem!
MAIN FEATURES:
- World Leading technology
- The state-of-art fully DSP technology with output isolation transformer
- Super wide input voltage/frequency range, adapt to harsh utility environments
- Soft start with settable time 6-100seconds , more compatible with generator
- Output power factor 1.0optional, and output short-tolerant capability
- Intelligent self diagnosis, mass memory(10000 events) to record operation log
- Super long MTBF≧200000 hours, and short MTTR
- Intelligent parallel up to 8 units and parallel ECO Mode.
- Most intelligent digital equal current parallel technology,self-load share algorithm
- Single and parallel mode ECO available
- Independent cooling system, muti-protection design, ensuring high reliability with harsh environment and load
- Output short-tolerant ability,
- ABM battery technology, extremely low ripple current extending battery lifespan
- Lithium ,Ni-cd, Lead -Acid battery acceptable
- Frequency convertor mode function
- Power walk-in function, protecting rectifier during the transferring process from battery to AC mode
- Emergency Power Off(EPO)
- Super Reliability
- Fully DSP control with output isolation transformer, super reliability.
- Redundant SPS,fan etc. design, enhancing system reliability.
- Build-in output isolation transformer, eliminate neutral to ground drifting voltage, and isolate load harmonic current influence to inverter.
- Besides highest design technology,only qualified famous brand components used.
- Conformal-coating PCB fixed in sealed box,keeping away from outside effect
3.Communication interface:
- Build-in various communication connectors (RS232, RS485, AS400etc).
- Optional cards available: SNMP, battery management kit,
- Lighting proof module, dust proof filter etc.
- Cold start function
- Easy Operation
- Front side maintenance, top or bottom wiring connection, with protective equipment.
- Friendly human machine interface, with 7inch touch screen
Specification:
Capacity | 100kVA | 120kVA | 160kVA | 200kVA | 250kVA | 300kVA | 400kVA | ||
90kVA | 108kW | 144kW | 180kW | 225kW | 270kW | 360kW | |||
Input | Wiring connection | Three hase+Ground | |||||||
Nominal yoltage | 380/400/415VAC | ||||||||
Voltage range | 285VAC~498VAC | ||||||||
Frequency | 50/60Hz | ||||||||
Frequency range | 45-65Hz | ||||||||
Soft start | 5-600sec settable | ||||||||
Power factor | 0.95(with input filter) | ||||||||
Bypass | Nominal yoltage | 380/400/415VAC(Three phase+Neutral+Ground) | |||||||
Frequency | 50/60Hz±10% | ||||||||
Voltage range | ±10%,±15%,±20%settable | ||||||||
Output | Nominal voltage | 380/400/415VAC(Three phase+Neutral+Ground) | |||||||
Voltageregulatior | ±1%(balance load),±2%(100%unbalance load) | ||||||||
Power factor | 0.9(1.0 optional) | ||||||||
Dynamic response | ±5%(0~100%load transient | ||||||||
Distortion | <1%(100%linear load), <3%(100%non-linear load) | ||||||||
Transient response | <5ms | ||||||||
Sync.Range | ±2Hz(±0.5—±3Hz settable) | ||||||||
Overload | 105%continue,110%1Hr,125%10min,150%1min | ||||||||
Frequency | ±0.05% | ||||||||
Waveform | Pure sine wave | ||||||||
Efficiency | Inverter mode | Up to 94% | |||||||
ECO mode | 98% | ||||||||
Parallel | N+X | Max 8 units | |||||||
Battery | Configurtation | 12V,32 pieces default(30~34pieces settable) | |||||||
Display | LCD +LED | ||||||||
Physical | Dimension (mm) |
Depth | 855 | ||||||
Width(6P) | 890 | 1245 | 1640 | 2265 | |||||
Width (12P) |
1415 | 1770 | 2265 | 2265 | |||||
Height | 1900 | ||||||||
Weight | 6P | 960 | 1075 | 1630 | 2105 | ||||
12P | 1390 | 1672 | 2250 | 2500 | |||||
Environment | Temperature | 0-40℃ | |||||||
Humidity | 0-95%non condensing | ||||||||
Noise()m) | ≤67dB | ||||||||
Communication | RS232/RS485 | Support windows2000/XP/7/Linux/Unix/Mac | |||||||
SNMP(OPTIONAL) | Support remote control through web browser | ||||||||
Standard | Anti-thunder | D grade | |||||||
Safety | IEC60950-1,IEC62040-1-1 | ||||||||
EMC | IEC62040-2,IEC62040-3 |