Product Details:
Payment & Shipping Terms:
|
Product Name: | High Frequency Ups | Input PF: | ≥0.99 |
---|---|---|---|
Input Frequency: | 40-70hz | Charge Voltage: | 275Vdc |
DC Voltage: | 240Vdc | Optional: | SNMP/AS400/USB |
High Light: | online power supply,online uninterruptible power supply,ECO Online High Frequency UPS |
PC + TX Online High Frequency UPS / Split Phase UPS 6KVA - 10KVA
1.DSP control ,with excellent performance and comprehensive protections for load and UPS ;
2. Output power factor 0.9,offering more stronger load capability;
3.Intelligent fan speed control ,with 4 levels varying to load and temperature;
4.Wide input range ,support kinds of generator;
5.Dual input AC source supportable
5. EPO(emergency power off);
6.Event log up to 100 events, recording UPS running time and critical memories ;
7.Configuable output both 120/ 240Vac
8.N+X parallel redundancy, up to 6units
9.AC and cold start function;
10. Human friendly large LCD, with plenty operation information
11. Conformal coating PCB for more critical operation environment
12. Multiple communication ports (optional)
13. Maintenance bypass (option)
Technical Specification
Model |
PCP6K -TX |
PCP6KS -TX |
PCP10K -TX |
PCP10KS -TX |
|||||||
Capacity(Kva/kW) |
6KVA/5.4kW |
10KVA/9kW |
|||||||||
Input PF |
≥0.99 |
||||||||||
Input voltage |
Phase |
2Lines |
|||||||||
Low transfer |
L-L:176 VAC ± 3% @ 100% load;130 VAC ± 3% @ 50% load |
||||||||||
Low back |
L-L188 VAC ± 3% @ 100% load,142 VAC ± 3% @ 50% load |
||||||||||
High transfer |
L-L 286 VAC ± 3% |
||||||||||
High back |
L-L:270 VAC ± 3% |
||||||||||
Input frequency |
40-70hz |
||||||||||
Battery |
|||||||||||
quantity |
external battery |
20PCS*12V*9Ah |
external battery |
20PCS*12V*7Ah |
|||||||
Back up time |
depend on external Battery |
6mins @ full load |
depend on external Battery |
4mins @ full load |
|||||||
DC voltage |
240Vdc |
||||||||||
Charge voltage |
275Vdc |
||||||||||
Recharging current |
4A/8A(option) |
||||||||||
Output |
|||||||||||
Output P.F |
0.9 |
||||||||||
Output voltage |
110/220Vac or 120/240Vac +/-1%(static) |
||||||||||
Frequency |
46~54Hz or 56~64Hz (Line mode) |
||||||||||
Crest factor |
3:1(max) |
||||||||||
Wave distortion |
Less than 2%(linear load), Less than 4% Non-linear load |
||||||||||
Over load |
105%<load<125% for 1 mins ,125%<load<150% for30sec |
||||||||||
Efficiency |
88%(Line mode) |
||||||||||
87%(AC mode) |
|||||||||||
Transfer time |
0ms (AC-Battery); |
||||||||||
0 ms(bypass-inverter) |
|||||||||||
Indicator |
|||||||||||
LCD Panel |
UPS status, Load level, Load watt,Load VA,Battery level, Input/Output voltage, output current,Bus voltage, Temp, and warning and fault code and events |
||||||||||
Alarm |
|||||||||||
Battery Mode |
Sounding every 4 seconds( can mute) |
||||||||||
Low Battery |
Sounding every second |
||||||||||
Overload |
Sounding every second |
||||||||||
Fault |
Continuously sounding |
||||||||||
Management |
|||||||||||
Smart RS-232/USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC |
||||||||||
Optional |
SNMP/AS400/USB |
||||||||||
Environment |
|||||||||||
Operation Humidity |
0-90 % RH (non-condensing) @ 0- 40°C |
||||||||||
Noise Level |
Less than 55dBA @ 1 Meter |
Less than 60dBA @ 1 Meter |
|||||||||
Physical |
|||||||||||
Net Weight (KG) |
62 |
120 |
160 |
206 |
|||||||
Gross Weight(KG) |
74 |
132 |
180 |
249 |
|||||||
UnitDimension (D*W*H)mm |
509*250*530 |
600×300×810 |
600*300*742 |
600*300*892 |
|||||||
Packing (D*W*H)mm |
650*363*765mm |
680*360*960 |
720*420*920 |
720*420*1070 |
|||||||
Note:All specifications subject to change without further notice; customized specifications are acceptable
Contact Person: Mr. Hunter Chen
Tel: +8615818502906