24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer

Product Details:

Place of Origin: Shenzhen China
Brand Name: HRD/OEM
Certification: CE
Model Number: R7000

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: 5000USD
Packaging Details: standard for export
Delivery Time: 5-6weeks after deposit
Get Best Price Contact Now

Detail Information

Color: Gray (Ral 7035 Input: 220/230 Single Phase Or 3phase 380/400/480Vac
Input With TX: Input Isolation Transformer Input Range: 220/230+15%;3phase 380/400/480Vac+/-15%
Input Fz: 45-66Hz Ouput DCv: 24,48.60,110,125,110,220Vdc
IP Degree: IP21-IP43 Cable Entry: Bottom
Operation Temperature: 0-40centigrade Capacity: 2.4kw To 220kW
High Light:

24VDC Rectifier Battery Charger

,

48VDC Rectifier Battery Charger

,

220VDC Rectifier Battery Charger

Product Description

R7000 Series Industrial Charger & DC UPS, With Input Isolation Transformer, 24VDC,48VDC, 110VDC,125VDC,220VDC

 

Introduction:R7000  series 2.4kw to 220kW industrial rectifier is specially designed for harsh industrial application environment with high performance application requirements. It provides high reliability, high performance and high quality DC power.

R7000 industrial rectifier is designed on thyristor technology, the rectifier can charge nickel cadmium battery and lead-acid battery and supply DC load at the same time. It can also be used as independent DC power supply without battery.

 

 

Perfect Applications:

 

P e t r o l e u m , petrochemical, power plant, natural gas, electric power, marine, heavy industry, mining, transportation and other industries .

 

Features and benefits:

    1)SCR rectifier with DSP control technology, overvoltage,undervoltage protection for reliable operation in all mains conditions

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 0 2)Input isolation transformer for AC- DC

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 1 3)High operating safety and reliability, even under difficultcircumstances over long periods of time

 

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 24) Adjustable manual and automatic charging mode for maximum flexibility on operation

 

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 3 5)Digital control panel and touch screen for meters, alarms,and history events for maximum flexibility on monitoring

 

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 4 6)Parallel operation for redundancy requirements

 

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 5 7) Support all charging mode for vented/sealed lead acid batteries and Ni- Cd batteries

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 6 8)More than 12,000 history records to position issues quickly and accurately

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 7 9) Front accessibility for easy maintenance

 

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 8 10)Battery charging temperature compensation

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 911) Cable voltage drop compensation

Technical specificaions:

 

Input

Rated voltage 230Vac 1phase or 400Vac 3phase
Voltage range 230Vac+/-15% or 400Vac+/-15%
Frequency range 45-66Hz

 

 

Output

Rated voltage 24,48,60,110,125,220Vdc
Operating Voltage

Floating:75%-125% of rated voltage at full load and rated voltage+/-10%

Equalizing:75%-125% of rated voltage at full load and rated supply voltage(0-10%)

Commissioning:75%-140% of rated voltage at half load and rated supply voltage(0-10%)

 

Static voltage regulation +/-0.5%
Ripple Voltage ≤1%
Charging characteristic IU( according to DIN41773)
System and Environmental Protection degree IP21(Optional to IP43)
Cable entry bottom
access front
Color RAL7035
Operation temperature 0-40 centigrade
Storage temperature -25-70centigrade
Noise <65dBA
Altitude <1000m(derating according to EN62040-3)
Cooling Forced Ventilation

 

 

Standard

Safe IEC60146
EMC

IEC61000-6-2

IEC61000-6-4

Performance IEC601146
Communication RS-232/485,Modbus Protocal

 

 

 

 

 

 

 

Rating

Rated Voltage(Vdc) 24 48/60 110/125 220

 

 

 

 

 

 

 

Rated Current(A)

25 25 25 25
50 50 50 50
75 75 75 75
100 100 100 100
150 150 150 150
200 200 200 200
300 300 300 300
400 400 400 400
500 500 500 500
600 600 600 600
800 800 800 800
1000 1000 1000 1000

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 10

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 11

24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer 12

 

 

Want to Know more details about this product
I am interested in 24 48 110 125 220VDC Industrial Charger With Input Isolation Transformer could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.