Smart data centre 208Vac Online Ups High Frequency UPS On Line
Product Details:
Place of Origin: | Shenzhen China |
Brand Name: | HRD/OEM |
Certification: | CE,ISO9001:2008 |
Model Number: | PWA3310,PWA3315,,,PWA3380 |
Payment & Shipping Terms:
Minimum Order Quantity: | 5PCS |
---|---|
Price: | 2100USD/PCS |
Packaging Details: | 1pcs/ctn, wooden case with pallet |
Delivery Time: | 4 weeks after down payment |
Payment Terms: | TT or LC |
Supply Ability: | 1000PCS/month |
Warranty: | 2-3 years aftershipment with 10years technical support |
Detail Information |
|||
Highlight: | three phase online ups,double conversion online ups,high frequency online ups |
---|
Product Description
Smart data centre 208Vac Online Ups High Frequency UPS OnLine
Introduction:
Smart Data center 208Vac Online Ups High Frequency UPS OnLine
Powerwell (America)series 3 phase 10-80kva is a high end uninterruptible power supply, which has adopted the world leading electrical and electronic technology to increase performance and super high reliability(MTBT>200,000h).3nos high speed DSPs with completed digital control fully ensure highest quality of power supply and UPS reliabitly. Being kin to 1.0 input power factor and less than 2% THDi lead this UPS green and energy saving. It also offers humanization design: full front access of service ability, user- friendly touch screen.
Perfect Applications:
Internet Servor ,Middle Data Center, Medium-scale network system / computing center, bank and securities, business server group, Medium-scale office automation, precision equipment, etc.
Features: complete digital control technology
Fully digital control with two DSPs, all the subsystems are digital controlled including the IGBT rectifier, inverter, charger, discharger.
Excellent electrical properties
True online double conversion instruction offers the safe and effective power protection for various loads, with strong output load capacity;
High input power factor, green and energy-saving
Input end with PFC and input PF of the whole UPS up to 0.999,;
Dual AC input source supportable
Allowable AC and bypass 2 input ac source
Strong environmental adaptability
Wide input voltage and frequency range, adaptation to all kinds of climatic
and geographical environment;
Comprehensive protection measures
Surge Protection, short circuit protection, and other protection to ensure the reliability of UPS;
IGBT and SCR adopts the advanced EUPEC power module;
The adoption of advanced technology (IGBT driving technology, IGBT soft over-current shutdown) improves the reliability and safety of inverter.
Similar modular design
Each phase main board are designed like rack for easy assembling and maintenance
Inbuilt battery pack plug-in design for easy use
Intelligent battery management (ABM)
Adopting the intelligent battery management:
Intelligent charger:interval three-stage charging process( constant current,constant voltage, float charging and charger shut off, when battery voltage decrease to a lower level, charger restarts to work)
Back up time displayed on the LCD screen
Battery temperature compensation
Online detecting battery status,
The max battery charging current can set by end users according to the battery features, to avoid any damage caused by the big charging current;
Periodic self-test battery, detecting the battery problems timely;
With battery inverse connection, over voltage / current protection, to protect the battery;
Cold start and AC start Function
Directly start the UPS through battery or start UPS through Mains only.
Superior network monitoring capabilities
Communication port (RS232, USB, and so on) connecting with computer,SNMP card optional,
Easy-maintenance design
a) Adopts the full front maintenance design, reducing the restrictions
on the installation space, and saving the space of computing center;
b)Modular design class, convenient and easy site maintenance;
c) With manual maintain bypass,
d)Battery replacement without disrupting the UPS running;
e) Historical records search function, events up to1,000 items;
Friendly interface with Large LCD
Large LCD display and LED status indication; Abundant information display of UPS;
Technical Specifications:
Model |
PWA3310 |
PWA3315 |
PWA3320 |
PWA3330 |
PWA3340 |
PWA3360 |
PWA3380 |
|||||||
Capacity/Rating Power |
10Kva/9Kw |
15Kva/13.5Kw |
20Kva/16Kw |
30Kva/27Kw |
40Kva/36Kw |
60kva/54kw |
80kva/72kw |
|||||||
AC Input |
||||||||||||||
Rated voltage |
190/208/220Vac (Line-Line) |
|||||||||||||
Input connection |
3 phase +N+PE |
|||||||||||||
Power factor |
Above 0.999 |
|||||||||||||
THDi |
Less 2% |
|||||||||||||
Voltage range |
150-270Vac (Line voltage) |
|||||||||||||
Frequency |
40-70Hz |
|||||||||||||
Bypass |
150-270Vac (Line-Line)+/- 15% |
|||||||||||||
Output |
||||||||||||||
voltage precision |
±0.5% |
|||||||||||||
Dynamical voltage transient |
Less 5% ( 0~100% load step) |
|||||||||||||
THDU |
THD less 0.6%( linear load ),3%(non-linear load) |
|||||||||||||
Power factor |
0.9 (lag) |
|||||||||||||
Frequency tracking range |
50/60Hz±3Hz |
|||||||||||||
Frequency precision |
±0.05%(Battery mode) , ±3hz(Line mode) |
|||||||||||||
phase displacement |
120±0.5°(Balance or imbalance load ) |
|||||||||||||
Frequencytracking rate |
Less 1Hz/s |
|||||||||||||
Overload capability |
105% long time operation |
|||||||||||||
125%,transfer to bypass after 10 minutes |
||||||||||||||
Above 150%, transfer to bypass after 1s |
||||||||||||||
Bypass overload |
Above 180%, long time operation |
|||||||||||||
Above 180%, last for 1s |
||||||||||||||
Transfer time |
0ms |
|||||||||||||
System |
||||||||||||||
System efficiency |
Above 91%(Normal mode);96%(ECO) mode |
|||||||||||||
Display |
Touch screen LCD+LED |
|||||||||||||
EMC |
IEC62040-2 |
|||||||||||||
IEC61000-4-2 (ESD) |
||||||||||||||
IEC61000-4-3 (RS) |
||||||||||||||
IEC6100-4-4 (EFT) |
||||||||||||||
IEC6100-4-5 (Surge) |
||||||||||||||
Noise (1m) |
Less 60dB |
|||||||||||||
Insulating resistance |
Above 2M (500VDC) |
|||||||||||||
Insulating intensity |
(input, output to PE) 2820Vdc, leakage current lower than 3.5mA, no flashover in 1min |
|||||||||||||
Surge protection |
Meet the requirement of IEC60664-1class,endure surge of 1.2/50us+8/20us higher than 6KV/3KA |
|||||||||||||
IP class |
IP30 |
|||||||||||||
Battery configuration |
||||||||||||||
Installation(dc) |
+96/108/120Vdc ,- 96/108/120Vdc(settable from LCD screen) |
|||||||||||||
Connection |
Bottom cable connection in front |
|||||||||||||
Charger |
1-20A( settable) |
|||||||||||||
Dimension (W×D×H) |
Long-run model |
620×800×1100 |
720×900×1850 |
735*850*1680 |
||||||||||
Inbuilt batt. |
620×800×700 |
720×900×1050 |
954*839*1857 |
|||||||||||
Weight (kg) |
Long-run model |
40 |
60 |
70 |
120 |
130 |
150 |
160 |
||||||
Inbuilt batt. |
125 |
145 |
180 |
300 |
340 |
**** |
**** |
|||||||
Note:Any specification subject to change without notice;