Product Description

Smart Power Distribution Unit

Fully intelligent control, network encryption HTTPS SNMPv3, isolation, remote upgrade

1,System Introduction

HRD smart power distribution units (PDU) provide multiple power distribution port with complete protection, With rich configuration and complete functions, users can choose corresponding products according to needs, makes establishing data centers and integrated computer rooms more efficient.

 

 

Pic. 1-1 Horizontal PDU

Smart PDU 0

Pic. 1-2 Vertical installation of 24-bit PDU single-phase/three-phase

Smart PDU 1

 

Pic.1-3 Vertical installation of 20 PDUs

Smart PDU 2

Pic.1-4 Vertical installation of 16 PDUs

2,System Feature

2.1,High performance

◆The double-precision high-tech calculation method provide accurate electric energy measurement and power factor data for a single socket.

Smart PDU 3◆Colored LCD display

It adopts a color LCD display to visually display voltage, current, power factor, electric energy, IP address, temperature and humidity, CAN/485 hardware address and other information.

◆Provides real-time power monitoring

High efficient data processing methods, real-time data monitoring for input current, voltage, power, power factor, electrical energy, frequency, etc., also the monitoring and control PDU can display current, power factor and energy of each socket, with curve image display function.

◆ Available for remotely turn on/off a single socket

Monitor and control PDU could management each sockets through HTTP, SNMP, SSH and other network protocols , At the same time, various protocols can provide encrypted SSL to make remote control more secure and reliable.

◆Socket metering function provided

Provide users with a basis for accurate calculation of PUE, plan and optimize the energy consumption of the data center based on this, reduce costs for load balancing and IT environment set up.

◆ Customized allowed alarm threshold set can warn potential circuit overload by real-time and remote alarm lower the risk.

◆ Advanced switch function, can realize user-defined logic control and independently realize the switch action and schedule of each socket position, also take intelligent actions according to environmental changes.

The user can control the PDU output switch according to the current threshold and temperature threshold, and provide multiple alarm at the same time. There is a parameter copy function between the sockets. After setting the parameters of one socket, it can be quickly copied to other sockets. With socket management function PDU, each socket can be controlled according to the time setting by user, it can realize 20 user-defined time period editing to meet the complex needs .

◆ Socket sequencing delay, in order to avoid circuit overload, and can customize the time

When switching sockets or powering on, the power-on time interval can be flexibly set between sockets, which is conducive to stable operation of the load and avoids surges.

◆ With socket grouping management function

PDU with single socket management, users can customize socket grouping, flexible socket grouping is conducive to user classification management of sockets. The hardware is also divided into 3 groups independently, each with 8 sockets. Each 8-bit socket of the three-phase PDU is also electrically isolated.

◆ Users can access and configure via a secure Web, SNMP, SSH or Telnet interface, easy to operate and integrate.

◆ Provide 2ways temperature and humidity sensor, 3 ways input and 1way output port

◆ Provide isolated CANbus, RS485 serial networking mode

The PDU not only provides common SNMP management functions in data centers, but also collects data and controls equipment through serial methods such as CAN bus and RS485. In small and medium-sized data centers or environments without network conditions, the PDU can provide multiple integration methods to facilitate secondary development for users.

◆ Compatible with Jeidar SNMP Link network management system.

SNMP Link provides power equipment management and environmental parameter detection for the dynamic environment monitoring system of Jeidar small and medium data centers. The equipment that SNMP Link can manage includes power distribution cabinets, PDUs, ATS, UPS, air conditioners and other equipment. For details, please refer to the SNMP Link description.

2.2,Multiple network service

  • Provide HTTPS management, support TLS Encrypted authentication

HTTP supports standards above TLS1.0 and has a high security level.

  • Provide SNMP v3 Agent, support DES or AES authentication method. Provide MD5 or SHA private encryption

Provides SNMP function for re-developing and facilitate the integration of other software with SNMP network management SNMPv3 also provides encryption protection.

  • Support Telnet and SSH

Support network command line to view and operate devices, and SSH provides network security encryption.

  • Support network firewall. Provide network protection such as data packet filtering and anti-PING. Have a more reliable network security level.
  • Provide NTP time synchronization settings

Network clock synchronization, this function can provide accurate device time when the device is connected to the Internet.

  • Provide operation, event log and battery time record

Event log mainly records equipment operations and alarms, and the operation log provides equipment data records, including equipment input and socket output information, and power records.

  • Support PDU upload and download power records.

This function is mainly used for quick configuration of batch PDUs. The user can set the parameters of a PDU, then download the parameters of the PDU, and upload the parameters to other PDUs of the same type to realize the rapid configuration of the device. At the same time, setting parameters can also be downloaded and backed up. Once reset is required, quick configuration saves time.

2.3,Safe and stable

  • Internet security

Support TLS Encrypted authentication, SNMPV3 communication, Alternative encryption, SSL mail sending, support network firewall.

  • Electrical Safety

All external sensor interfaces and communication interfaces are isolated. Further improve the electrical performance of equipment and communication security.

  • Memorable state restoration

When an abnormality occurs and the device is restored, it has the ability to maintain the original state of the memory and restore it quickly.

 

  • Latest Linux kernel version 4.0+ and cryptographic libraries. Repair most of the system security holes.
  • Provide online software upgrades to meet special application scenarios and reduce maintenance costs.

3,Specification :

Function Types
Basic Centralized Monitoring Each Socket Monitoring and Control
Input power detection
Input voltage detection
Input current detection
Input capacity detection
Input power factor detection
Input frequency detection
Temperature/Humidity detection
Dry contact detection
Relay alarm output linkage
Each sockets output current detection  
Each sockets output capacity detection  
Each sockets current Upper/Lower limited  
Each sockets output power calculate  
Each sockets output switch control    
Each sockets sockets on/off time setting    
Sockets group management  
 

Note: ●indicates that this series of products has this function.

4,Input and output specifications with size

Horizontal PDU (single phase)

Smart PDU 4

Pic. 4-1 Horizontal PDU outlook

No. Remark No. Remark
1

Standard: Overseas 8-bit 10A international standard C13 output socket; domestic 8-bit national standard 3-hole

Non-standard: accept customization

9 Scroll
2 8* light indicator 10 Reset
3 Colored LCD display 11 Running indicator
4 NET 10/100M port 12 Hanger
5 Input 485/CANBUS 13 Input breaker 16A/1P (optional)
6 Output 485/CANBUS 14 PDU Input or IEC-C19
7 IO port 15

Standard configuration: Overseas customers specify the output method (excluding wires); domestic national standard Samsung

Optional input is IEC-309 industrial connector, etc.

8 SENSOR (Temperature/Humidity)    
 

Note: Horizontal PDU has 9 different input and output modes.

Vertical PDU (Single phase):

Smart PDU 5

No. Remark No. Remark
1

24outputs:

Standard: Overseas 21-bit 10A international standard C13 output socket

Domestic 21-bit 10A national standard 3-hole output socket

20 digits:

Standard: Overseas 16-bit 10A international standard C13 output socket

Domestic 16-bit 10A national standard 3-hole output socket

16 outputs:

Standard: Overseas 12-bit 10A international standard C13 output socket

Domestic 12-bit 10A national standard 3-hole output socket

9 Confirm/ Scroll
2

24 outputs:

Overseas 3-position 16A international standard C19 socket

Domestic 3-position 16A national standard 3-hole output socket

20 digits:

Overseas 4-bit 16A international standard C19 socket

Domestic 4-bit 16A national standard 3-hole output socket

16 outputs:

Overseas 4-bit 16A international standard C19 socket

Domestic 4-bit 16A national standard 3-hole output socket

10 Reset
3 2.4inch LCD display 11 Running indicator
4 NET 10/100M network port 12 Each indicator
5 Input 485/CANBUS 13 Input breaker 16A/1P or 32A/2P (optional)
6 Output 485/CANBUS 14 PDU input
7 IO port 15

Standard configuration: Overseas customers specify the output method (excluding wires); domestic national standard Samsung

Option: input end is IEC-309 industrial connector 16A, etc.

8 SENSOR port(Temperature & Humidity) 16 24outputs indicator, 16outputs indicator
 

Pic 4-2 Appearance of vertical single-phase PDU

Vertical PDU (Three phase):

Smart PDU 6

Pic 4-3 Appearance of vertical three-phase PDU

No. Remark No. Remark
1

Standard: Overseas, three-phase output, each phase 7-bit 10A international standard C13 output socket;

Domestic, three-phase output, each phase 7-bit 10A national standard hole output socket

9 Confirm/ Scroll
2

Standard: Overseas, three-phase output, each phase 1 bit 16A international standard C19 output socket

Domestic, three-phase output, each phase 1 bit 16A national standard 3-hole output socket

10 Reset
3 2.4inches LCD screen 11 Running indicator
4 NET 10/100M network port 12 Each indicator
5 Input 485/CANBUS 13 Input switch 16A/3P or 32A/3P (option)
6 Output 485/CANBUS 14 PDU input
7 IO port 15

Standard input terminal (without power cord)

Option input is IEC-309 industrial connector 32A

8 SENSOR port(Temperature & Humidity) 16 24outputs indicator

 

5,PDU Remote Monitoring

Smart PDU 7

JPDU remote monitor topology

 

6,PDU naming

Smart PDU 8

7,Main parameter list of intelligent series products:

7.1 Horizontal 8 outputs intelligent product main parameter table (single phase):

Output
Rated output voltage 220Vac
Overload protection Available
Max. current consumption 16A
Output sockets

Standard: Overseas 8-bit IEC 320 C13; domestic 8-bit national standard 3 holes

Non-standard: accept customization (such as: national five holes, American style, etc.)

Input
Rated Input Voltage 200Vac/ 208Vac/230Vac
Input Frequency 50/60 Hz
Input Terminal block

Standard: Overseas customers specify the output method; domestic national standard Samsung

Non-standard: accept customization (such as: IEC 309 32A 2P+E, national standard, American standard, European standard, British standard, etc.)

Cable length 2.5m
Input voltage range 220-240Vac
Cable quantity 1(optional)
Bear capacity 3700VA
Max. input current 16A
Max. circuit current 16A
Physical parameter
H 44mm,4.4cm(without connector)
W 436mm,43.6cm(without hander)
D 168mm,16.8cm (without air switch)
Installation cover distance 460mm,46.0cm(with hanger)
N.W. 2.9kg
G.W. 3.6kg
pkg height 120mm, 12.0cm
Pkg width 500mm,50.0cm
Pkg depth 400mm,40.0cm
Enclosure material SGCC metal sheet
Color Black
Environment
Working Temperature -5 - 55 °C
Working Humidity 5 - 95 %
Working Altitude 0-3000 m without derating
Storage Temperature -25 - 75 °C
Storage Humidity 5 - 95 %
Storage Altitude 0-15000m
Warranty
Standard warranty 2years
 
RoHS Conform
Battery directive Available

Warm reminder: The above parameters are for reference only, in case of technical upgrade parameters change, it is recommended to consult the online customer service for the actual parameters of the product.

SGCC is hot-dip galvanized steel. S means steel, G means galvanized, C means cold rolled, and C means common grade. Advantages of SGCC: anti-rust, anti-corrosion, strong weather resistance.

7.2 Vertical PDU specification --24/20/16outputs(Single phase):

Output
Outputs quantity 24 20 16
Rated output voltage 220Vac
Overload protection available
Max. current consumption 16/32A
Output sockets

standard:

Overseas 21*IEC 320 C13;

3*IEC 320 C19

Domestic 21*10A national standard 3 holes;

3*16A national standard 3 holes

Non-standard: accept customization

standard:

Overseas 16*IEC 320 C13;

4 * IEC 320 C19

Domestic 16*10A national standard 3 holes;

4*16A national standard 3 holes

Non-standard: accept customization

standard:

Overseas 12*IEC 320 C13;

4*IEC 320 C19

Domestic 12*10A national standard 3 holes;

4*16A national standard 3 holes

Non-standard: accept customization

Input
Rated Input Voltage 200Vac/ 208Vac/230Vac
Input Frequency 50/60 Hz
Input Terminal block IEC 309 32A 2P+E
Cable length 2.5m
Input voltage range 220-240Vac
Cable quantity 1(optional)
Bear capacity 3700VA /7400VA
Max. input current 16/32A
Max. circuit current 16/32A
Physical parameter
Height 1829mm,182.9cm(without connector) 1400mm,140.0cm(without connector)
Width 56mm,5.6cm
Depth 47mm,47cm (without air switch 39mm)
N.W. 8.23kg 6.83kg
G.W. 10.5kg 8.8kg
Pkg Height 2038mm,203.8cm 1609mm,160.9cm
Pkg Width 162mm,16.2cm
Pkg Depth 118mm,11.8cm
Enclosure material SGCC metal sheet
Color Black
Environment
Working Temperature -5 - 55 °C
Working Humidity 5 - 95 %
Working altitude 0-3000m non derate
Storage Temperature -25 - 75 °C
Storage Humidity 5 - 95 %
Storage Altitude 0-15000m
Warranty
Standard Warranty 2years
 
RoHS Conform
Battery directive Available

Note: The above parameters are for reference only, in case of technical upgrade parameters change, it is recommended to consult the online customer service for the actual parameters of the product.

SGCC is hot-dip galvanized steel. S means steel, G means galvanized, C means cold rolled, and C means common grade. Advantages of SGCC: anti-rust, anti-corrosion, strong weather resistance.