3 In 3 Out MODULAR UPS 25 - 400 KW Higher Sustainability Energy Saving
Product Details:
Place of Origin: | CHINA |
Brand Name: | HRD/MOTU/OEM |
Certification: | CE |
Model Number: | ZY |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Payment Terms: | L/C, D/A, D/P, T/T |
Detail Information |
|||
Brand: | HRD/MOTU/OEM | Color: | Black |
---|---|---|---|
Model: | ZY | Feature1: | Full UPS Functioned |
Feature2: | 3ph In To 3ph Out | Feature3: | CE Certificate |
Highlight: | uninterruptible power supply,double conversion online ups |
Product Description
ZY SERIES UPS 25-400 kW
Lowest total cost of ownership and maximum availability – taking scalability, resiliency, safety and efficiency to the next level.
The most advanced UPS in its power range, the HRD ZY is ideal for small to mid-sized data centres and other mission critical applications where efficiency, reliability, safety and scalability are essential.
Future-ready
The rapid adoption of the cloud, constant evolution of IT technologies, increased focus on environmental footprint and sophistication of mission critical applications is demanding even more efficient, resilient, scalable and safe power protection solutions.
The new levels of efficiency and scalability offered by the ZY minimise Total Cost of Ownership while the safety and resiliency, both in infrastructure and IT layers, maximise availability and ensure business continuity.
All-round value
Available in 200kW frame sizes, the modular design of the ZY enables it to suit a wide range of requirements. And, whichever one you choose, you can be sure it will provide the lowest Total Cost of Ownership combined with maximum availability, for cost-efficient business continuity.
Ensuring that you can always access the power your mission critical application requires – under all circumstances – without compromising business performance or safety, the ZY is the most efficient, scalable, Cloud-ready and safe UPS you can choose.
Efficiency
With high efficiency being translated into reduced electrical and cooling losses, it helps to minimise operational expenditure costs, in addition to addressing the cost pressures esulting from commoditisation of IT services. Increased efficiency also leads to higher sustainability, through reduced carbon emissions.
Scalability
Scalability helps to optimise capital expenditure by only deploying additional equipment when necessay and providing additional flexibility to respond to your changing needs. The scalability of the ZY also
provides increased flexibility to accommodate the changing requirements of rapidly evolving technologies.
Resiliency, virtualisation & cloud-readiness
The ability of a system to absorb faults and still remain in its desired operational state is paramount to minimising costly downtime. The ZY takes resiliency to the next level by bridging electrical and IT infrastructures.
Safety
Ensuring safety in any electrical installation is a must. Safe hot-swappable design and in- built back-feed protection ensures safety and compliance with regulations.
Maximum Energy Efficiency Lowest TCO
the ZY series is simply the most efficient UPS in its class, offering the lowest total Cost of ownership. thanks to the advanced algorithms and energy- saving features, the ZY achieves up to 99% efficiency. this efficiency is well proven with installations in major datacentre hubs in the Asia Pacific region and around the world.
99% efficiency - Energy Saver System (ESS)
The ESS enables the ZY efficiency to reach an impressive level of 99% by suspending the power modules when power conditioning is not required.
The power is fed through the static bypass switch, and in the event of exceeding pre-set input limits, the UPS is ready to switch to double-conversion mode in under two milliseconds. In addition to extremely low losses, the ESS mode provides filtering against fast low-energy transients. It is simply the most advanced, most reliable, fastest-reacting energy-saver architecture available.
In addition to saving energy, this technology enhances the reliability of the system by reducing electrical stress in the power electronic components, extending the UPS life time and thus reducing total cost of ownership.
Efficiency in all modes
Load (% of nominal)
optimised double conversion efficiency - Variable Module Management System (VMMS)
For applications where ESS may not be optimal, for example with very low quality mains, VMMS technology includes automatic variable power module management. The system automatically suspends and engages modules as appropriate, to optimise efficiency both at UPS and system level.
VMMS helps you achieve high efficiency even when UPS load levels are low – typical for redundant UPS systems. VMMS can optimise the load levels of power modules in a single ZY UPS or in parallel systems, by suspending extra UPS capacity. This means not only greater efficiency at lower load levels, but optimum efficiency at all load levels.
The ZY UPS 25kW UPM (Uninterruptible Power Module)
Maximum double conversion efficiency
The ZY UPS still offers the highest double conversion efficiency in the market, reaching
above 96%.
Highest power density
The unity power factor maximises the true available power of the ZY UPS. This means it can deliver up to 20% more real power than other in it's class.
The highly scalable nature of the ZY UPS means that scaling up in response to increased demand takes minutes rather than hours. Scaling up can also be achieved without increasing the footprint – saving valuable floor space. The modular design allows for internal redundancy, which eliminates.
The scalability can be reached by paralleling up to 4 frames for a total system size of up to 800 kW.
Maximum Availability
Maximum availability is integral to business continuity, and integral to the design of the HRD ZY UPS. It ensures you can always access the power your mission- critical application requires.
Hot swappable and hot scalable
Due its modular design, a ZY power module can be replaced or added while another module continues protecting the load. This eliminates the need to go to bypass for module replacement or upgrading (MTTR: 0 minutes). Replacement and upgrade (N+1) operations typically take less than 10 minutes.
Centralised topology
The centralised topology of the ZY is ideal for scalable systems, as it provides full bypass capacity from day one, whereas modular designs with static switches in every power module can have a severe
negatIve impact on the selectivity of the system due to undersized static bypass. This can compromise the availability of the overall system.
Take complete control
Managing and controlling your ZY UPS is easy. Designed for the most advanced It environments, the ZY comes equipped with intuitive user interfaces, a large touchscreen LCD providing useful status information and back logs, and a full suite of power management and connectivity options.
the complete solution
The HRD ZY UPS is designed for the most advanced IT environments, and it comes with interfaces for Web and SNMP as standard.
In the event of an alert, the UPS system notifies users and administrators by email. If there’s a prolonged power failure, the protected computer systems can be shut down smoothly using the Intelligent Power® Protector software also incorporated with the ZY.
Your ZY can be connected directly to your corporate network and the internet. This means you can monitor and manage your UPS through a standard web browser.
Information, access, ease of use
Intelligent Power Manager® (IPM) can be used to monitor and manage all Intelligent Power Protectors running in the network. This dramatically reduces the administrator’s workload, and minimises the possibility of error.
The web-based interfaces of the Intelligent Power software simplify usage, by allowing access from any computer in the LAN, as well as remotely via the internet. Power information is consolidated in the same tool used to monitor and manage physical and virtual servers, storage and networks.
In the event of power failure, IPM can trigger protective actions such as live migration of virtual machines, controlled shutdown, or disaster recovery.
Intelligent, intuitive, integral
The world-class Intelligent Power Manager intelligent software solution of your ZY UPS plugs into leading virtualisation management systems, including VMware vCenter, Microsoft SCVMM and Citrix XenCenter.
This user-friendly monitoring tool enables you to monitor and manage your UPS system as an integral part of your power infrastructure. It collects data through the network, then stores it in a database for viewing and analysis.
Easy management
The ZY UPS provides easier access to detailed status information through its large, user-friendly 7” LCD touchscreen interface.
With the graphical LCD interface you can track stats on energy savings, battery time, outage tracking, load profiling and much more.
The green/yellow/red LED light-bars make system status visible from a distance in data centres.
HRD ZY UPS UPS 25-400 kW
Technical specifications
General | ||
UPS output power rating (1.0 p.f.) | 25, 50, 75, 100, 125, 150, 175, 200kW | |
Efficiency in double conversion mode | > 96% | |
Efficiency in Energy Saver System (ESS) | > 99% | |
Static bypass rating | 200kW | |
External paralleling | up to 4 units with HotSync technology | |
UPS topology | Double conversion | |
UPS degree of protection | IP20 | |
Acoustic noise at 1 m, in 25 °C ambient temperature | < 70 dBA in double conversion, < 55 dBA in ESS | |
Altitude (max) | 1000m above sea level at 40 °C. Maximum 2000m with 1% derating per each add. 100 m | |
Input | ||
Rated input voltage | 220/380 V, 230/400 V, 240/415 V 50/60 Hz | |
Voltage tolerance - Rectifier input | 187 to 276 V | |
Voltage tolerance - Bypass input | rated voltage -15% / +10% | |
Rated input frequency | 50 or 60 Hz, user configurable | |
Frequency tolerance | 40 to 72 Hz | |
Input wiring | 3 phase + neutral | |
Input power factor at 100% load | > 0.99 | |
Input ITHD | < 3% | |
Rated input r.m.s current | 25kW 50kW 75kW 100kW 125kW 150kW 175kW | 200kW |
380V | 40 A 80 A 120 A 159 A 199 A 239 A 278 A | 318 A |
400V | 38 A 76 A 114 A 151 A 189 A 227 A 264 A | 302 A |
415V | 37 A 73 A 110 A 146 A 182 A 219 A 255 A | 291 A |
Soft start capability | Yes | |
Internal backfeed protection | Yes | |
Output | ||
Output wiring | 3 phase + neutral | |
Rated output voltage rating | 220/380 V, 230/400 V, 240/415 V, configurable | |
Total voltage harmonic distortion | < 1% (100% linear load); < 5% (100% non-linear load) | |
Output power factor | 1.0 | |
Permitted load power factor | 0.8 lagging to 0.8 leading | |
Overload on inverter | 10 min 102-110%, 60 sec 111-125%, 10 sec 126-150%, 300 ms > 150%. | |
Overload on bypass | Continuous < 125%, 20 ms 1000% | |
Battery | ||
Battery type | 12V, VRLA | |
Charging method | ABM technology or Float | |
Temperature compensation | Optional | |
Battery nominal voltage (VRLA) | 480 V | |
Battery quantity | 36 to 44 blocks. Default is 40 blocks | |
Charge current limit | Default 5A, configurable maximum 25A per UPM | |
Battery start capability | Yes | |
Communications | ||
Minislot | 3 communication bays | |
Network/SNMP interface | Yes, optional | |
Serial ports | Built-in host and device USB | |
Standard connectivity ports | Mini-slot ports for optional cards, Device USB and Host USB, RS-232 service port, relay output, 5 building alarm inputs and a dedicated EPO | |
Accessories | ||
MiniSlot connectivity (Web/SNMP, ModBus/Jbus, Relay) External Battery Cabinet(EBC) Parallel Tie Cabinet(PTC) External Maintenance Bypass Switches(EMBS) External Battery Cabinet Breaker(EBCB) |
||
Compliance with standards | ||
Safety | IEC 62040-1 | |
EMC | IEC 62040-2 | |
Performance | IEC 62040-3 |
Part Number | Description | Rating | Dimensions(WxDxH)mm | Nett Weight(kg) |
Power module | ZY UPS 25kW (UPM) Uninterruptible Power Module | 25KW | 460 x 600 x 130 | 28 |
ZY-100kW Frame | ZY UPS 100kW Frame, internal back-feed | 100KW max | 603 x 1013 x 1650 | 260 |
ZY-200kW Frame | ZY UPS 200kW Frame, internal back-feed, MBS | 200KW max | 603 x 1013 x 2050 | 368 |
Due to continuous product improvement programmes, specifications are subject to change without notice.