30kVA UPS Power Module, Double DSP control
Scalable from 30 kVA to 300kVA. Parallel-capable up to 2400 kVA.
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
HQM-A MODULAR UPS 30-300kVA,0.9PF
3:3Phase,208Vac/208Vac
Truly modular UPS
Full functioned UPS Module
HQM-A modular UPS is double DSP controlled green UPS, adopted with double high speed DSP to ensure its excellent performanc,reliability and flexibility. It delivers the best combination of rectifier, filter, charger, inverter and intelligent power protection. Applying innovated current sharing rectifier control, master-slave synchronization in sequence control, multi-level decentralized control and 3-level inverter technolog,
HQM Modular architecture can scale power as demand grows or as higher levels of availability are required.
Main Features:
- Great performance index, 7inch touch screen
overall efficiency ≥ 95%(AC-AC), inverter efficiency ≥ 98%(DC-AC), THDI ≤ 3%, and input PF ≥ 0.99
- N+X module-level redundancy UPS System
- Multi-level decentralized control technology and Master-slave synchronization in sequence control which result in eliminate system failure bottleneck
- Each Power module can work separately with LCD display
- And automatically shares the input and output current, all UPS modules share batteries
- Intelligent Battery management:
- Battery discharge management, auto-transfer between floating and even charging, temperature compensation
- Space-saving high density design, Rack-based for agility and aesthetics
- Abundant Monitor Function
30 kVA UPS module (PMA3330)
Adaptable 30 to 300 kVA power capacity
30 kVA UPS module
Components: STS module, Monitor module, UPS module,Power distribution
Top or bottom feed
Module dimension(D*W*H):580x443x225mm
UPS MODULE TECHNICAL SPECIFICATION:
Power Rating | 60kVA | 90kVA | 120kVA | 150kVA | 180kVA | 300KVA |
60kVA/54kW | 90kVA/81kW | 120kVA/108kW | 150kVA/135kW | 180kVA/162kW | 300kVA/270kW | |
Main Input | ||||||
Grid System | 3 Phases + Neutral + Ground | |||||
Rated Input Voltage | 200/208/220VAC (Line-Line) | |||||
Rated Frequency | 50/60Hz | |||||
Input Voltage Range | 166~261Vac (Line-Line),full load 125V~166Vac (Line-Line),load decrease linearly according to the min phase voltage | |||||
Input Frequency Range | 40Hz~70Hz | |||||
Input Power Factor | >0.99 | |||||
Input Current THDi | <3% (full Linear Load) | |||||
Bypass Input | ||||||
Rated Bypass Voltage | 200/208/220VAC (Line-Line) | |||||
Rated Frequency | 50/60Hz | |||||
Bypass Voltage Range | Selectable, default -20%~+15% Upper limit: +10%, +15%, +20%, +25% Lower limit: -10%, -15%, -20%, -30%, -40% | |||||
Bypass Frequency Range | Selectable, ±1Hz, ±3Hz, ±5Hz | |||||
Bypass Overload | 125%, long time operation 125%< load <130%, last for more than 10 minutes 130%<load<150%,last for more than 1 minutes >1000%, last for more than 100ms | 110% Long term operation 110%~125% for 5min 125%~150% for 1min 150%~400% for 1s >400% ,less than 200ms | ||||
Output | ||||||
Rated Inverter Voltage | 200/208/220VAC (Line-Line) | |||||
Rated Frequency | 50/60Hz | |||||
Output Power Factor | 0.9 | |||||
Voltage precision | Balance load: ±1%; Unbalance load: ±1.5% | |||||
Transient Response | <5% for step load (20% - 100% -20%) | |||||
Transient recovery | < 30ms for step load (0% - 100% -0%) | |||||
Output Voltage THDu | <1.5% from 0% to 100% linear load <6% full non-linear load according to IEC/EN62040-3 | |||||
Inverter Overload | <110%, 60min; 110%~125%,10min; 125%~150%,1min; >150%,200ms | |||||
Frequency Regulation | 50/60Hz±0.01% | |||||
Synchronized Range | Settable, ±0.5Hz ~ ±5Hz, default ±3Hz | |||||
Synchronized Slew Rate | Settable, 0.5Hz/S ~ 3Hz/S, default 0.5Hz/S | |||||
Battery And Charger | ||||||
Battery Rate Voltage | ±120VDC | |||||
Charger Voltage precision | 1% | |||||
Charger Power | max=20% *Output power | |||||
Efficiency | ||||||
Normal Operation | >93% | |||||
Battery Operation | >93% | |||||
System | ||||||
Display | LED + LCD + touch screen | |||||
Interface | Standard:RS232, RS485, USB,Dry contact(Programmable ) | |||||
Optional:Battery Cold Start(Standard above 150kVA) SNMP,AS400,parallel kit,Lightning protection components | ||||||
Environmental | ||||||
Operation Temperature | 0 ~ 40 ℃ | |||||
Storage Temperature | -40 ~ 70 ℃ | |||||
Relative Humidity | 0 ~ 95% Non condencing | |||||
Noise (1 meter) | 65dB @ 100% load, 62dB @ 45% load | |||||
Altitude | <1000m, Load derated 1% per 100m From 1000 ~ 2000m | |||||
Phisical data | ||||||
Dimension | 600*980*1150 | 650*960*2000 | 650*960*1600 | 650*960*2000 | 650*960*2000 | 1300*1100*2000 |
Weigh (kg) | 210 | 305 | 350 | 445 | 490 | 900 |